Sliding-window (Section)#
Path: /facilities/data-sources/data-source{id}/data-source-alarms/failed-communication-alarm/sliding-window
Alarms that enforce a sliding window require a set amount of faults to occur within a set time-frame of each other (the sliding window) before they are raised.
Parameters#
| Name | Type | Required | Default | Description |
|---|---|---|---|---|
| faults-to-raise-alarm | uint16 | optional | 2 | The number of faults required to occur within the span of the sliding window for an alarm to be raised. Setting this value to 1 effectively disables the sliding window; raising alarms immediately as faults occur. |
| sliding-window-duration | uint16 | optional | 10 | The size, in seconds, of the sliding window applied to the alarm. Not all alarms enforce sliding windows; those that do are especially noted in their description.Setting this value to 0 effectively disables the sliding window; raising alarms immediately as faults occur. |