Alarm-severity-assignment-profile (Section)#
Path: /alarms/alarm-profile{alarm-type-id, alarm-type-qualifier-match, resource}/alarm-severity-assignment-profile
The client can override the system-default severity level.
Parameters#
| Name | Type | Required | Default | Description |
|---|---|---|---|---|
| severity-level | multi-value, severity | optional | Specifies the configured severity level(s) for the matching alarm. If the alarm has several severity levels, the leaf-list shall be given in rising severity order. The original M3100/M3160 ASAP function only allows for a one-to-one mapping between alarm type and severity, but since YANG module supports stateful alarms, the mapping must allow for several severity levels. Assume a high-utilization alarm type with two thresholds with the system-default severity levels of threshold1 = warning and threshold2 = minor. Setting this leaf-list to (minor, major) will assign the severity levels as threshold1 = minor and threshold2 = major |